HID® EDGE EVO® Hi-O Interface Modules

Interface for any EDGE EVO controller or reader/controller to standard door devices and readers
  • EDGE EVO Hi-O Interface Modules Access Controller And Reader
Overview | Specifications

The EDGE EVO® Hi-O Interface Modules provide door and extended IO interface between discrete IO and an EDGE EVO Controller. The interface modules provide a securely located IO interface to door components such as locks, door position inputs and REX inputs.

The modules also enable the expansion of IO monitoring and control, all connected back to one single-door controller with the potential to power everything over PoE. The modules include models EDWM-M, EDM-M, EWM-M, EIM-M, ELM and EVM.

Additional highlights

  • EDWM-M Door/Wiegand Module, provides four inputs, two outputs and Wiegand/Clock-and-Data reader interface.
  • EDM-M Door Module provides interface of up to four inputs and two outputs (for door specific use or general purpose).
  • EIM-M Input Module provides interface of up to four inputs.
  • EWM-M Wiegand Module provides interface with one Wiegand or Clock-and-Data reader.
  • ELM Lock module provides interface to a single lock / AUX output.

Modules come in one of six types; maximum two of each can be connected to any one EDGE EVO controller or reader/controller.

  • EDGE EVO Hi-O Interface Modules Access Controller And Reader
Overview | Specifications


EDWM-M

Part #: 82363AKM

Purpose: Interface EDGE EVO Controller ( / Reader) Hi-O CANbus to 4 inputs, 2 outputs and 1 Weigand / C&D Reader

Default Use: Interface to door RTE, DPS and Lock and Wiegand reader

Mounting: US Single-gang and EU / APAC 60mm mounting holes for electrical box mount

Dimensions: 3.3" W x 5.0" H x 1.5" D (84.0 mm x 127.0 mm x 37.0 mm)


EDM-M

Part #: 82342AKM

Purpose: Interface EDGE EVO Controller ( / Reader) Hi-O CANbus to 4 inputs, 2 outputs

Default Use: Interface to door RTE, DPS and Lock and Wiegand reader

Mounting: US Single-gang and EU / APAC 60mm mounting holes for electrical box mount


EWM-M

Part #: 82360AKM

Purpose: Interface EDGE EVO Controller ( / Reader) to 1 Wiegand / C&D Reader

Default Use: Interface to Wiegand reader

Mounting: US Single-gang and EU / APAC 60mm mounting holes for electrical box mount


EIM-M

Part #: 82340AKM

Purpose: Interface EDGE EVO Controller ( / Reader) Hi-O CANbus to 4 inputs

Default Use: Monitor general purpose inputs around the door

Mounting: US Single-gang and EU / APAC 60mm mounting holes for electrical box mount


ELM

Part #: 82301AN

Purpose: Interface EDGE EVO Controller ( / Reader) Hi-O CANbus to 1 lock

Default Use: Use for door control; reader / controller is hooked up to 1 lock output only

Mounting: Fits within US Single Gang Box or Hollow Door Frame


EVM

Part #: 82365AT

Purpose: Interface EDGE EVO Controller ( / Reader) 24VDC Hi-O CANbus to a 5-16VDC Hi-O iCLASS Reader

Default Use: Used strictly with Hi-O iCLASS Readers (sold separately)

Mounting: Fits within US Single Gang or EU / APAC 60mm electrical box

  • EDGE EVO Hi-O Interface Modules Access Controller And Reader
Overview | Specifications